General specifications | |
---|---|
Sensing range | 60 ... 500 mm |
Adjustment range | 60 ... 500 mm |
Dead band | 0 ... 60 mm |
Standard target plate | 10 mm x 10 mm |
Transducer frequency | approx. 300 kHz |
Nominal ratings | |
Time delay before availability | 250 ms |
Limit data | |
Permissible cable length | max. 300 m |
Indicators/operating means | |
LED green | Power on |
LED yellow | solid: switching state switch output flashing: misadjustment |
Electrical specifications | |
Rated operating voltage | 24 V DC |
Operating voltage | 15 ... 30 V (including ripple) In supply voltage interval 15 ... 20 V sensitivity reduced to 20% ... 0% |
Ripple | ? 10 % |
No-load supply current | ? 60 mA |
Input | |
Input type | 1 Function input |
Input voltage | ? Operating voltage |
Level | low level : 0 ... 3 V high level : ? 15 V |
Switching output | |
Output type | 1 switch output PNP, NO |
Default setting | 60 ... 500 mm |
Operating current | ? 300 mA , short-circuit/overload protected |
Voltage drop | ? 3 V |
Analog output | |
Output type | 1 voltage output 0 ... 10 V , rising ramp |
Default setting | 60 ... 500 mm |
Linearity error | ? 1.5 % |
Load resistor | ? 2 k? |
Compliance with standards and directives | |
Standard conformity | |
Approvals and certificates | |
UL approval | cULus Listed, General Purpose |
CSA approval | cCSAus Listed, General Purpose |
CCC approval | CCC approval / marking not required for products rated ?36 V |
Ambient conditions | |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Shock resistance | 30 g , 11 ms period |
Vibration resistance | 10 ... 55 Hz , Amplitude ± 1 mm |
Mechanical specifications | |
Connection type | Connector plug M12 x 1 , 5-pin |
Degree of protection | IP65 |
Material | |
Installation position | any position |
Mass | 500 g |
8 (029) 555-8-000 | |